英国论坛
7月份买的flat,看房的时候锅炉正常工作,上周末开了4个小时也正常工作,然后关闭,昨晚想再开,但是打开储藏室门时就发现alarm频闪,(照片上是正常工作的绿灯,现在是最顶端的alarm红灯闪)暖气不热。但是热水从来都是正常供应,蓝色的水包两个出水管(一个进厨房,一个进浴室)都是热的,请西北大哥给判断一下,多谢!
回帖
说明书在这里:
http://www.heatraesadia.com/docs/Amptec_-Issue_4-_36005871.pdf
Alarm闪灯也有三种情况,你对照一下吧:
12.0 FAULT FINDING
1 Should the alarm indicator illuminate ‘flashing’ (red) instantly on power up, then the connections ‘Conn 4’have become loose or disconnected in transit or if the ALARM indicator is ‘flashing’ (red) and the CALL indicator is (red), then ‘Conn 3’ or the thermostatic switch wires have become loose.
2 Should the alarm indicator illuminate ‘flashing’ (red) during the call checking period then there is a problem due to lack of water or air in the system.
3 Should the ALARM indicator illuminate ‘flashing’ (red) and the CALL light show (red) after heat is applied then there is a problem due to lack of water flow. See Fault Finding chart.
回帖
求银子……