Functions,Boiler,Mountings,ste business, insurance Functions of Boiler Mountings on a steam boiler
As we all know to live in this world we have to perform some activity by which we can earn money. There are many activities by which we can earn money and meet the standards to live in this society. And from one of them is franchise. Franc Small offices have unique needs, and thatincludes document shredding. Designed with the smaller business inmind, the Dahle 20314 is a cross-cut shredder that offers Level 3security and brings you into compliance with federal regulations. The
Boiler Mountings These are the fittings, which are mounted or installed on the boiler for its appropriate and safe workingWater level indicatorPressure gaugeSafety valveSteam Stop valveBlow off cockFeed check valveFusible plugMountings Descriptions1. Water Level IndicatorLocation: This fittings may be seen in front of the boiler.Function: To indicate the water level inside the boiler.Water level indicator are generally two in number.2. Pressure GaugeLocation: It is fixed in front of the boiler.Function: To measure the pressure of the steam inside of the steam boiler.Pressure gauges generally used are of Bourden type3. Safety valveLocation: These are attached to the steam chestFunction: To blow off the steam for preventing explosions when the pressure of the steam inside of the boiler exceeds the working pressure.Safety Valve generally used are of Spring loaded safety valve. 4. Steam Stop valveLocation: It is usually fitted to the highest part of the shell by means of a flanges.Function: a) To control the flow of steam from the boiler to the main steam pipe. b) To shut off the steam completely when required5. Blow off cockLocation: It is located at the bottom of the boiler.Function: To empty the boiler whenever required & To remove the mud, scale or sediments accumulated at the bottom of the boiler.6. Feed check valveLocation: It is fitted to the shell slightly below the normal water level of the boiler. It is a non return valve, fitted to a screwed spindle to regulate the lift.Function: To regulate the supply of water, which is pumped into the boiler by the feed pump.7. Fusible plugLocation: It is fitted to the crown plate of the furnace or the fire box.Function: To put off the fire in the furnace of the boiler when the level of water in the boiler falls to an unsafe limit and thus avoids the explosion which may place due to overheating of the furnace plate.
Functions,Boiler,Mountings,ste